m*l 发帖数: 507 | 1 or WaterCAD?
I need to model a booster pump to increase the flow through the pump to
400gpm.
How should I set up the model to do that?
Thank you very much! |
z****o 发帖数: 373 | 2 In waterCAD, add a flow control valve with 400gpm setting.
【在 m*l 的大作中提到】 : or WaterCAD? : I need to model a booster pump to increase the flow through the pump to : 400gpm. : How should I set up the model to do that? : Thank you very much!
|
m*l 发帖数: 507 | 3 Do you mean model the booster pump as a reservoir + FCP?
Thanks. |
j********l 发帖数: 325 | 4 What do you really want? An booster location where you can inject mass or a
regular pump. IN epanet, click the junction assumed to be booster location,
then change the source quality property. Normally, take source tpye as mass
booster. If you just want to add a pump, it's easy. |
m*l 发帖数: 507 | 5 Thanks.
All I want is to achieve a flow of 400gpm after the pump. From a book I
learned that setting a pump usually starts by modeling the pump as a
reservoir in a steady state simulation to figure out the pressure needed.
Then find a pump that meets that pressure and flow in more detailed design
and modeling. |
m*****g 发帖数: 62 | 6 booster pumps are used for increase/keep the pressure |
P*****y 发帖数: 30 | 7 Mel, I'm not quite sure I fully understand your question. If what you want
is just to increase the flow through the pump, then assign a downstream
demand node of 400 gpm and you will see a 400 gpm increase at the pump
assuming you are pumping to a closed system with no tanks or other supply.
It might help if you can elaborate on what you are trying to get out
of this modeling exercise. System head curve? Pump selection? |