由买买提看人间百态

topics

全部话题 - 话题: furnace
1 2 3 4 5 6 7 8 9 10 下页 末页 (共10页)
l********u
发帖数: 616
1
来自主题: Living版 - Furnace and AC 价格以及品牌推荐
最近AC坏了要换新的,正好furnace也有26年了,想着一起换掉省得过两年又坏了再换
。找了contractor来看,给了几个option:
1.Airease (这个是他现在最推荐的)整套 $ 6800
- Two stage gas furnace with DC fan furnace 90,000 BTU,95% efficient
- 13/14 sheer 3 ton air conditioner with matching coil and line set
- Comfort sync Wifi programmable thermostat
- Lifetime on BOTH STAINLESS STEEL heat exchangers, 12 year parts, 12 years
labor on furnace, 12 years compressor, 12 years parts and 12 years labor on
AC
- first year tune-up on furnace and AC in price
- removal an... 阅读全帖
s*******3
发帖数: 52
2
先说我家情况:现有是trane (furnace 是trane XE80,140,000BTU, ac 是high
efficiency,5吨,不知道具体型号,或者待会我出去看看),3000 尺 single house;
built in 1993, 新泽西; Summer from June to September 90F to 100F; Winter
from November to April 30F to 45 F; 原装系统; 一个zone 空调。冬天和夏天最高
电费360,春秋120样子,就是差不多240刀是空调费用。
最近空调坏了,回家发现很热,lg下去查看,跳闸了,外面风扇压缩机都没声不转了,
合闸不行,一合上就立刻跳。然后关了空调等了一夜,第二天早上可以合闸,开了以后
ac的风扇转,但是出气不凉,来人给看说压缩机坏了。建议全换,因为空调已经很老了
。拿到报价,几个选择,都是lennox机器:
1.Homedepot contractor Basic($7520): furnace/ac ML180UH110P60C, 14ACX060,
包括coil但不知道型号... 阅读全帖
s******n
发帖数: 212
3
【 以下文字转载自 Living 讨论区 】
发信人: stoneren (酸菜鱼), 信区: Living
标 题: 更新:furnace修好了- Gas Furnace点完火就灭问题
发信站: BBS 未名空间站 (Sun Jan 9 14:50:30 2011, 美东)
更新
终于在降温之前把furnace修好了。(症状参考附帖)
结果多少有点出乎意料,Control Board也就是Blower所在那个铁盒里的电路板后面发现一条
死去多时都差不错被风干的小lizard,手指长,整个就黏在电路板背面。看来是其死后分泌的体液
造成电路板线路问题。于是为了防止意外碰到furnace的电源保护按钮,把总电源也关闭,然后用
纸巾沾一点水把电路板背面清洁一遍,用电吹风吹干,上电,重新点火,终于看到了久违的flame
LED light。
在此,特别感谢一下icewatering和她推荐的海尔冷暖气公司的方师傅(281-777-1266
houston/katy/sugarland地区的朋友们有福啊)。
http://mitbbs.com/article_t/Texas/3137344... 阅读全帖
s*********t
发帖数: 16647
4
☆─────────────────────────────────────☆
AdamsMyIdol (F3) 于 (Tue Dec 6 15:19:18 2011, 美东) 提到:
发信人: AdamsMyIdol (F3), 信区: Living
标 题: 请教关于gas furnace 的问题
发信站: BBS 未名空间站 (Tue Dec 6 15:18:59 2011, 美东)
房子用的是gas furnace(搬进来才几个月)。最近天冷了,发现要用很长时间才能把
家里加热起来。
我把白天家里没人的时候的温度设成55度,然后从5pm 开始,设成70度。等到7pm回家
的时候,房间里才63度左右的样子(室外温度是32度左右)。
感觉热得太慢了。以前住condo的时候从50度加热到70度很快就好了,不过是用电的
furnace。我去gas furnace边观察了一下,发现它大概是这样工作的:燃烧加热一会儿
(感觉同时也在送暖风),燃烧停止,只能听见送暖风的声音。这样送一会暖风后,再
燃烧加热。房子的保暖应该可以,也没觉得哪里漏风。
就是觉得这个加热过程太慢,想问... 阅读全帖
d*******s
发帖数: 2689
5
来自主题: Living版 - 急问,是不是要换furnace了
我家gas furnace型号是383KAV042091,牌子是Bryant, 生产于2003年,到现在有11 年
了。
今年冬天天气冷,所以gas furnace一直开则着,室内一直保持72度左右。这个月发现
gas furnace 发出异常声音。这声音像耳鸣,吱吱的,尖叫四秒,停四秒,再尖叫四秒
,停四秒,如此往复,很烦人。gas furnace 在地下室,这声音我在一楼都能听见。
昨天找了service plus 的人来看,他说是inducer motor 的问题,charge 了我$79诊
断费.
选择1,换inducer motor,要价$851.
选择2, 由于我的gas furnace 已经11年了,建议换新的gas furnace, RHEEM牌的,要价
$5505.
选择3, 由于我的furnace 上面的central air conditioning 也已经11年了,虽然没毛
病,建议换新的gas furnace 时顺便也换central air conditioning, RHEEM牌的,
furnace + central air conditioning ... 阅读全帖
n********e
发帖数: 1789
6
Not sure your problem.
Mine once had issues because I used a FINE air filter (supposed to be good,
but not suitable for my funace), which blocked the air from flowing efficien
tly. So my furnace ran for a while then shut down because of over-heating pr
otection.
Finally, I bought another filter (larger holes) and it worked ever since.
Good luck.

房子是9月份close的,8月中旬作的Home Inspection。当初没有发现furnace有问题
然后到了10月底11月初,家里装修要换laminate地板,需要把Laminate在家里70F放3天
这个时候我们才第一次开暖气,发现furnace有问题。打开furnace,它是work的,但是
... 阅读全帖
f*********s
发帖数: 51
7
来自主题: Living版 - 请教换furnace
坐标加州湾区,买房后发现问题:
前屋主把furnace在一个很小的attic里面,attic的唯一入口是一个卧室墙上的closet
门,之前furnace不持续加热,找hvac的人来看,说attic太小,爬不进去,没法维修。
而且furnace和周围距离太近,不安全,不符合building code。现在的3个卧室的出气
口都靠近天花板,furnace旁边有一个duct向下通到crawl space里然后通到客厅的在地
上。air return是在3个卧室中间的ceiling上。
有个hvac contractor说,唯一的解决办法是把furnace从attic挪到卧室间走道的一个
closet里面,还说:
1. 必须要把3个卧室的通气口改到地板上,就是所有给气的duct都走crawlspace。Air
return位置不变。
2. 之前的furnace是horizontal装的,需要换成vertical装的才能用在closet里。同时
说现有furnace和ac吨位都不对。Furnace和ac要一起换。
3. 要买high efficiency的furnace,用pvc管子直接ven... 阅读全帖
s********w
发帖数: 487
8
房子是9月份close的,8月中旬作的Home Inspection。当初没有发现furnace有问题
然后到了10月底11月初,家里装修要换laminate地板,需要把Laminate在家里70F放3天
这个时候我们才第一次开暖气,发现furnace有问题。打开furnace,它是work的,但是
只要温度提高一度(20分钟左右),furnace就自己shut down了。每次只会increase一
度,达不到我们所设置的setpoint。
当时的home inspection是我们buyer的agent的推荐的,但是已经过了3个月,也不知道
找谁负责
于是我的agent说,我的seller帮我们买了home warranty,是American Home Shield
她说这个home warranty超级好的,肯定会帮我们把furnace修好
我满怀信心,11月8日submit了service request。他们在11/13请了一个contract来看
在我看来这个contract其实也不靠铺。第一次去楼下看了furnace,随便弄了一下之后
,说好了。让我交钱,签字。我正准备... 阅读全帖
i***e
发帖数: 9429
9
你这个已经是80%furnace,换新的也是80%,效率值是一样的, 你知道的哦?
这个furnace 未来要是换不要太容易。要师傅装和现在一样款的uncased coil(价格还
可便宜点).把新的coil安装的高度比老的coil高度高2寸(以coil 底部平面为基准),
这样会更方便。
而且。。。。而且。。。。而且。。。。
只要上面coil架在plenum 上, 或者左右用螺丝从侧面固定(师傅知道怎么做).未来当
换furnace 时只要拧开plenum 固定在furnace 上的固定螺丝,然后EAC 里边的固定螺
丝松掉,furnace 底部4块砖抽掉,furnace 即可脱离plenum.这个job 2000刀给俺们得
州的中国师傅做,人不要太爽。
如果装C33 cased coil,你未来换回TRANE furnace 也一样的贼容易,因为TRANE 的
furnace 是40寸高度,和你目前的XE80 一样高度。
你这情况不适合换成cased coil 如果你要保留furnace.
t*********g
发帖数: 71
10
来自主题: Living版 - 一些关于furnace的问题
地下室热水器漏了,喷出的水把furnace的electrical panel 和blower motor弄湿了。
现在fan不工作了, 没办法把冷气吹到屋里。 请了metro air services的人来看了,
说可能要换electrical panel, blower moter没准也得换。 他们建议说单换零件很贵
,不如直接换整个furnace,我们的furnace已经20年了,确实不太值得折腾换零件了
。Metro Air Services 给我们的quote是换8000 BTU 3.0 TON Drive Gas
Furnace是$1800。现在我有以下几个问题, 希望大家能给我一些建议。
1。我们的furnace和AC的Brand都是Carrier. 现在我们只换furnace. 需要选择和AC一
致的牌子吗?Metro Air建议我们装Amana instead of Carrier. 还有哪些牌子比较好
呀?
2. 这次属于accident, 应该可以claim home insurance. 值得吗?怕保险公司认为我
们是high risk,以后会涨保险。
3。我看... 阅读全帖
g*q
发帖数: 26623
11
那个大箱子一般是furnace+风扇(同时给空调和furnace用).但是有heat pump的话可能
HP就替代furnace了.当然也有可能有furnace做HP的backup,这种情况下可能furnace的
母火灭了或者有其他问题.
还有很多房子,一层楼是furnace+空调,另一层用heatpump.如果你家是这个情况,
furnace没开,可能是控制furnace的温控的问题.
s********w
发帖数: 487
12
我们家也是上个月月底刚刚保险公司给换了个新的furnace
之前保险公司派人来修了三次,换了三个parts,都没有修好
最后contract给保险公司汇报说,要直接换heat exchanger。估计这个很贵,所以保险
公司就直接给我们换了个新的furnace
我们自己copay了$550,其中包括gasline和pipe什么的。
我老公查了一下。好像换个新的furnace基本最少需要$2000(furnace+人工费,假如买
的是最便宜的furnace);但是平均大概需要$4000吧
但是换好之后,furnace确实比以前那个旧的好太多了。我老公说furnace的说明书也是
正规的,他看着那个contract亲手安装furnace的。
至于控温器,你自己去买一个就好了,这东西不贵。我们家换了个sensi的wifi的控温
器。如果contract要帮我们换,我们还不愿意呢
H****J
发帖数: 22
13
Imore 请看看下面的组合是否合理;
请参考首帖;
#3 furnace + #2 AC
AC: xc16- 4 ton 2 stage a/c unit model - XC16-048-230;
matching cased coil model - cx35-49c;
Furnace: 2 stage 96% 110,000BTU gas
furnace power saver motor model -EL296UH110XE60C;
根据你的经验, 价格应该比#2 便宜多少; 性价比是否更合理;
谢谢
---------------------
#1 ($14072)
Modulating variable speed 98% 110,000BTU gas furnace model - SLP98UH110XV60C
xc25- 4 ton modulating a/c unit model - XC25-048-230
Matching cased coil model - cx35-48c; wifi I comfort thermostat control
Heal... 阅读全帖
t*******r
发帖数: 3271
14
=======
情况介绍
=======
空调是分2个ZONE, 这里说的是楼上的ZONE, therm stats是霍尼韦尔的, furnace是
goodman的
我知道冬天therm stats/furnace的工作原理是实际温度低于设定温度时就开始工作(加
热)(实际可能有1-2度的温度偏移)
=======
故障现象
=======
经过一段时间以后, 会发现这么一种现象:
1, 实际温度已经很低, 绝对达到了furnace应该开始工作的状态;
2, furnace并未工作(如果开始工作, 就应该有风扇和转动的声音, 我可以听得到的);
3, Therm stats的状态是"heat on", 就是furnace应该加热时的状态;
<...此时系统好像陷入了一种halt的状态, 反正是不加热...>
4, 此时如果手动把therm stats关闭(设置为off), 然后再打开(设置为heat), 就可以
听到furnace开始正常工作并加热了.
========
我的问题
========
请教各位, 哪里出了问题? 是therm stats还是furnace本身?
是哪根控... 阅读全帖
j*********n
发帖数: 90
15
来自主题: Living版 - 什么是high efficiency furnace?
high effeciency 是 >92% AFUE. 现在的furnace 至少80% AFUE. high efficiency
furnace 要接PVC 管子把废气通到外面。如果你旧的furnace大小适当的话,用
90000BTU times 旧的furnace的efficiency 再除以新的furnace的efficiency 就是新
furnace的 BTU.80% efficiency 的furnace 可以仍然用chemney 排气
a****g
发帖数: 480
16
来自主题: Living版 - HELP! furnace is not working!
Some guys finished our floor sanding/polishing work, they directly connected
their equipment with the electric panel.
Then our bathroom light and vent were not working. and the furnace too.
We reset all the switch in the electric panel and bathroom light and vent
work again, but the furnace still not. we followed the furnace manual to
turn on the pilot light, we can see the flame, but the furnace seems not
starting at all.
somebody mentioned the meter to test if electricity available. I have a
m... 阅读全帖
s********w
发帖数: 487
17
来自主题: Living版 - Furnace Pressure switch cycle lockout
一个半月前曾经在板上请教过大家furnace的问题.
情况是,家里的furnace,开了之后,大概run 30分钟,就会自动熄火。于是我们需要
手动去restart furnace (关了再开)。家里thermostat设置70F,怎么都不会达到这
个setpoint,除非我们自己不停的手动restart
当初有位大侠说,可能是filter的问题。于是1个月前我们把filter拿走或者换了big
hole的filter,furnace就一直没有问题,运作良好。
这一个半月中间,home warranty派来的contract把control board给换了
可是自从这周开始,furnace老毛病又犯了
这次问题更加严重,不管是不是用filter,furnace都会自动shut down。
仔细看了一下,启动后,先是blow热气;然后中间有一段时间blow 冷气,查看了error
code,是3 flash red - Pressure Switch stuck open;接着再blow热气一段时间;
最后就熄火,报错的信号灯是6 flash red - Pressure switch... 阅读全帖
H****J
发帖数: 22
18
请imore 给参考,是否要换新的系统了。谢谢!
症状: AC 制冷效果不好。今年夏天温度高且持久;室外 90F;空调持续开,只能将1楼
和地下室的温度维持在77F左右。 晚上将空调设置到二楼,需一个小时左右才能将温度
降到75F左右。前年ac加了近1 lb 的ferran; 去年气候不是很热,空调制冷马马虎虎。
冬天室外20F, furnace will turn on every 10 to 15 min;
公司给了一个报价 for new furnace/ac ;只问了一家报价,有以下四种选择;如果
pay check 会有6% 折扣;
3000 尺 single house; built in 1999, in mid-west; Summer from June to
September 90F to 100F; Winter from November to April 15F to 45 F;
old system: Armstrong in 1999; with 85% efficiency; 1250 BTU;
#1 ($14072)
Modulating va... 阅读全帖
y*j
发帖数: 3139
19
要是我的话,就装那个home depot的HE机器。十年按照中国师傅也要省$3000,为什么
不装一个好的?更何况HE应该省的更多,如果你空调开的更大的话。HE也许寿命更长,
因为效率高,运行时间缩短。

:先说我家情况:现有是trane (furnace 是trane XE80,140,000BTU, ac 是high
:efficiency,5吨,不知道具体型号,或者待会我出去看看),3000 尺 single house
; built in 1993, 新泽西; Summer from June to September 90F to 100F; Winter
:from November to April 30F to 45 F; 原装系统; 一个zone 空调。冬天和夏天最高
:电费360,春秋120样子,就是差不多240刀是空调费用。
:最近空调坏了,回家发现很热,lg下去查看,跳闸了,外面风扇压缩机都没声不转了
,合闸不行,一合上就立刻跳。然后关了空调等了一夜,第二天早上可以合闸,开了以
后ac的风扇转,但是出气不凉,来人给看说压缩机坏了。建议全换,因为空调已经很老
了... 阅读全帖
s*******3
发帖数: 52
20
似乎很多人都是冷空调坏了,然后furnace/ac一起换,为什么呢?似乎furnace 不容易
坏的啊。我家空调系统22年了。
我的师傅建议furnace/ac全换,他说虽然我们的
furnace 还没坏,但是现在换的话,加个1600刀就能全换,如果现在只换ac,将来
furnace 坏了,要3,400刀来单换furnace, 因为到时候coil还要拆下来(铜管切断焊接
等),管道也要调整,因为新furnace 比旧的矮4,5寸样子,还要再申请一次permit,
人工费 都要加上,所以贵的多。现在换便宜很多。imore大牛给个意见, 有必要全换吗
?还是只换ac 呢?
s********g
发帖数: 60
21
来自主题: Living版 - Furnace报价求建议
打算换掉家里四十年的furnace,坐标湾区。furnace only,没有空调。1500 sqft的平
房,需要3 tons。furnace在hallway的closet里。问了6家,很多问题大家说法都不一
致。
配置:
由于气候不是很冷,我打算用80%。另外希望安静一点,所以用2 stage, variable
speed fan。这个配置怎样?
Permit需要吗?
有的说旧的换新的不需要permit,只是以后卖房时不能写upgraded furnace。有的说火
灾后没permit会被deny保险。有的一定要做permit。
石棉胶带要不要去掉:
旧furnace上面那个方的东西上有石棉做的胶带。有人说要先请专门contractor做
asbesto abatement来除掉,不然他们不能装,怕disturb asbesto。也有人说可以
ignore,放着也不会影响健康。
Permit中的title 24
加州有个title 24,要确保duct漏气不超过15%。有几个contractor要收几千块钱去
reseal duct。有一个小哥说由于furnace上有石棉,titl... 阅读全帖
c********e
发帖数: 4283
22
来自主题: Living版 - Furnace thermostat接口急问
long story short, 我换furnace filter的时候mess up了,没装好(是那种可清洗的
filter),结果filter和上面的薄塑料网格被进风的涡轮给吸住然后打圈,结果把
furnace里连接thermostat的电线给扭断了。
是gas furnace.
然后furnace就shut down了。我把电线重新接回去以后,furnace重新工作了。但是有
两点问题。
1.是furnace里还有段电线一头连着W1,另一头游离着,貌似是另外一根电线被缠绕着的
时候一起拽下来的,要请教的是,那游离的一头应该是连到那个端口的?
2.现在楼上的termostate调节温度的按钮都没反应了,以前存的温度设置好像在有作用
。但手动想要改变没有办法。换了电池依然。
我感觉furnace里的那个断头电线应该要接回去,似乎这个和楼上theomstate没反应应
该也有关系?
请教高手。
附图看楼下。
h*****g
发帖数: 1327
23
来自主题: Living版 - (已解决)Furnace不工作了,求救
Furnace型号是Lennox 80UHG4/5
昨天自己清理了一下Furnace,清理之前关掉了电源和gas管道的switch,做的工作包括
furnace内部的吸尘,flame sensor擦干净,更换了air filter和加温器的water panel
,把管道的挡风板拨到了冬天的位置。
今天早上气温比较低,然后我就打开furnace,结果发现出了问题。
Thermostat放到Fan on的位置的时候blower正常工作,说明blower没有问题。
Thermostat放到heater位置air inducer启动,说明air inducer电路没有问题。但是不
能自
动点火,等了约两三分钟,自动关闭,code提示pressure switch open or has opened
5 times during a single call for heat. 猜想可能pressure switch的问题。
重点放在pressure switch上面。
检查连接inducer和pressure switch之间的tube没有问题。
断电状态Pressure switch两个电... 阅读全帖
b****a
发帖数: 793
24
来自主题: Military版 - 基础知识heat pump vs gas furnace
Pros of heat pumps:
Work efficiently year-round. One investment can help you reduce your heating
and cooling bills.
More environmentally friendly. Heat pumps can create one-and-a-half to three
times more heat energy than they consume.
Cons of heat pumps
Typically more expensive than furnaces. Although, you are also getting an
efficient air conditioner.
May require a backup heat source. For extremely cold nights in Northern
California, backup or supplementary heat (such as a furnace) may be requi... 阅读全帖
i****m
发帖数: 699
25
来自主题: Living版 - 紧急求助: 换AC和Furnace
需要换楼下furnace 和二楼furnace + AC. 今天签了contractor 的proposal. 但后来
在网上查了一下, 不是很放心签的设备是不是合适,价钱也觉得高了。 大家帮我看
看:
1. 楼下furnace:
Trane XR80, Furnace model TUD1B080A936, BTUH 80000, AFUE 80. 价格:$2151
Installed
不换就的duckwork
2. 楼上furnace + AC
Furnace: Trane XV80, Model TUD2B080A9V3, BTUH 80000, AFUE 80
AC: Trane XR16, Model 4TTR6030, Seer 16
Coil: 4NXCB036AC
价格:$6196 Installed
不换就的duckwork
这周三就要来装了, 不只还能不能取消今天签的合同。
谢谢大家。
j*******a
发帖数: 2681
26
大冷天heater坏了-。-!
gas取暖 unit在房顶的attic
火苗打不着了
到底应该报修哪个?
Floor Furnace (Gas)
Forced Air Furnace (Gas)
Forced Air Furnace (Oil)
Wall Furnace (Gas)
我个人粗浅的觉得,floor furnace是地暖,heater应该是哪个furnace啊?
谢谢!!!
b********e
发帖数: 595
27
昨天给warranty公司发service request,今天上门来检查。
自从上次换了控制板,发现开一会儿就报33,furnace停止燃烧。
今天师傅来检查了一下,认为是排气不畅(我前面试过了把filter拆了,同样的问题,
所以师傅认为不是进气不畅)。至于排气不畅,我提出能不能检查一下vent,是不是堵
住了,能不能清洗一下?师傅说不会堵住,是damper是老型号的,其中一个区的damper
关了以后,damper是完全关闭,出风速度不够,导致furnace过热。新的damper设计在
一个区关闭的时候,这个区的damper还会开个口,我对这个说法就不能判断了,毕竟咱
也不是修furnace的,简单错误或者配件坏了还好判断。
问之前换控制板之前为什么没这个问题,解释说老控制板遇到过热不会锁住,只会熄火
再点火方式的循环,新控制板遇到过热会锁3个小时。不知道这个是不是真的?
问了怎么修理,师傅说要和warranty公司写个报告,一种是把gas掉小,这样楼下会更
冷,但是furnace不会过热。另外一个方法是更换damper,大概1200刀,但是不知道
warranty公司会不会批... 阅读全帖
h**********o
发帖数: 4127
28
18年的老furnace 检查下来是firebox有crack 另外heat exchanger也有问题 维修大哥
说是substantial safety issue 建议heat exchanger和furnace都换新的 麻烦在于当
年builder用了相对于房子面积来说过大很多的furnace和ac(维修大哥算的是furnace
2500 CFM 但供/进气才1200 CFM)所以大叔说如果只安装新的heat exchanger和小型
furnace而不换旧ac的话可能ac很快会出问题 但全套换下来人工材料都过万了 请问是
不是这样的情况可以只换heat exchanger或furnace啊?
b****n
发帖数: 379
29
今早起来发现furnace的electric panel switch跳掉了。重新开了之后,也能打着火,
但是好像只能在first stage。过了一会儿furnace旁边就有一些的烧木头的味道,但是
房间里出风口味道就很大了。赶快把furnace旁边的switch关了。当时humidifier是开
着的,关了之后,隐约能听到furnace里面好像有水慢慢滴下来的声音。把humidifier
把了之后过了一会儿再开furnace,看到错误指示灯三下三下地闪,也没有烧起来。然
后犯傻按了一个白色的按钮,感觉应该是reset吧???再重新关-开switch,又变成正
常的call for heat,烧起来了,但是不到1分钟(还没到温度)就shut off了,看了
flame sensor,没有deposit.
今年的furnace一开始就有点奇怪,好像一直都是一个stage(不是很确定),但是风好
像一直都特别热。
现在我不敢开暖气了。求教该怎么诊断。外面十几F!
s****z
发帖数: 1501
30
https://www.grainger.com/category/hvac-motors/motors/ecatalog/N-9xz?okey=
furnace+motor&mkey=furnace+motor&refineSearchString=furnace+motor&NLSCM=14&
EndecaKeyword=furnace+motor&searchBar=true&searchRedirect=furnace+motor#nav=
%2Fcategory%2Fhvac-motors%2Fmotors%2Fecatalog%2FN-9xzZ1z0o4ni%2FNtt-furnace%
2Bmotor%3FEndecaKeyword%3Dfurnace%2Bmotor%26NLSCM%3D14%26searchRedirect%
3Dfurnace%2Bmotor%26sst%3DAll
这家卖给个人
你如果可以看到你自己的型号 用他们的online chat
他们会告诉你换哪个

ECM
h******l
发帖数: 6
31
在湾区,一层房屋大概1800sq ft,打算把furnace挪到attic上,旧的机器淘汰。问了
一家报价9200刀。问加AC多少钱,还没回复。求大神帮忙看看价钱合不合理。
---
Summary of Work Requested
 Installation of new furnace system in attic
 Extend existing gas line and electrical to attic
 Install lights and outlet in attic
 Install Carrier top tier Infinity Series 59TN6 96% two stage
variable-speed furnace, 17.5” 60kbtuh
 Install new flue
 Install Nest thermostat
 Install R8 wireflex supply ducts (7x) connecting to ... 阅读全帖
s*********t
发帖数: 16647
32
来自主题: Seattle版 - [合集] 推荐我用的furnace师傅
☆─────────────────────────────────────☆
eastgate (东门) 于 (Mon Dec 5 02:22:56 2011, 美东) 提到:
Columbia Heating
206-708-0999
我装的是single-stage 80% AFUE (Annual Fuel Utilization Efficiency) furnace。
Overlake Heating 开价是 $1795 + tax。这个师傅(Mark,是白人)只收$1190+ $75
for programmable thermostat. 支付现金还不用给税钱。
☆─────────────────────────────────────☆
lihuahuhu (huhu) 于 (Mon Dec 5 12:48:36 2011, 美东) 提到:
自己买了什么东西?
还是完全省心全用他的?

75
☆─────────────────────────────────────☆
eastgate (东门) 于 (Mon Dec 5 15:2... 阅读全帖
a***u
发帖数: 335
33
furnace的出气管里有水,导致furnace不能正常排气而自动关闭。在furnace运行时,你可以听听出气管里是不是有水声。如果有的话,这是因为出气管位置过低,里面的水不能从furnace的排水管流出。你只要把出气管往上抬抬,让里面的水从furnace的排水管流出,就可以了。然后固定出气管。
c******e
发帖数: 350
34
来自主题: Living版 - 什么是high efficiency furnace?
现在打算将用烟囱的gas furncace更换成high efficiency 的.
在home depot上,想查查两种furnace大概会差多少.
却发现,我根本从名称上看不出来哪种furnace 是 high efficiency的.
请问,版上是否有高人可以科普一下么?多谢!
另外,high efficiency furnace有什么好处?
从安全角度,是不是有烟囱的furnace可以更好的将废气(一氧化碳什么的)排出房子
,会更好呢?
BTU大概如何选择呢?现在的旧furnace是90000BTU, 房子大概1200sqf.
多谢!
i***e
发帖数: 9429
35
来自主题: Living版 - Gas Furnace出问题了
这台是90%,2stage furnace.
furnace 开机流程都类似:
1。关闭furnace 电源,10秒后再打开电源。
2. 开暖气
3。draft inducer (小排气马达,在furnace 中间位置)开始启动。
4。25-45秒后,电热丝开始发亮(点火),
5。大约5-8秒后,主火点着。
6。60-90秒后,blower 启动,房间里的出热风。
核对你的furnace 点火流程,确认那一步出了问题,
电子版上LED会出现不同的闪烁频率,代表不同的error code. 记录下来。
找到说明书或在面板内侧,应该可以找到 error codes 的注解表,核对一下,顺便贴
图上来,目前我也找不到这台机子的service manual。
k*****k
发帖数: 381
36
买了个旧房子,在energy audit report里提到AC 30年了,furnace也快20年了。家里
没有通gas,是不是这个furnace其实是heat pump?
如果要把整个冷暖气系统全部换了,只需要换AC with heat pump就行了,还是要加
furnace的钱?版上大家讨论的AC和furnace一起换是因为大家都是用gas吗?
我quote下来Bryant 3ton 14SEER with heat pump是$5,500 with Tax and labor,有5
year labor warranty算贵吗?AC contractor说只要换这个就可以了,不用加furnace
因为没有gas
网上搜了搜,感觉一头雾水,在这里请教大家了!谢谢!
n****5
发帖数: 217
37
芝加哥郊区,2-story的SFH,大约3100 sqf。准备把furnace还有AC都换了。准备要3-4
个quote。
下面的是我迄今为止收到的.比较喜欢这个contractor,告诉我除非铁了心要在现在的
房子里面住很多年,根本没有必要上high efficiency,因为要很多年才能payback。并
且卖房子的
时候买家也不会多付钱。
X- Comfort Project:Trane XL80, 2-stage ($3520)
-remove and replace existing furnace with XL80, 2-stage furnace
-120,000 BTU
-4.5 ton blower drive
-includes all materials related to project
-includes labor, taxes and fees
X- Comfort Project:3.5 Ton XR13 ($3750)
-replace existing unit with Trane XR13
Condenser and matching ind... 阅读全帖
m*******1
发帖数: 58
38
还有当时房检的时候发现:The mechanical draft fan at the furnace vent appears
to have been installed backwards. The gas flow arrow points towards the
furnace. This can restrict proper draft. Corrosion staining was noted at the
draft fan in the furnace. This may be caused by the mechanical vent
installation. A licensed HVAC contractor is recommended to fully evaluate
the furnace and correct the mechanical vent as necessary.
看mechanical draft fan的箭头方向确实是反的,但是这个已经装了很多年了,并且房
检的时候启动没有问题。不知道这个是不是有问题?
还有当我手动断开Press... 阅读全帖
g***t
发帖数: 343
39
好像没有更好的地方能放furnace.
我现在对number of stages, fixed speed 什么的还是一头雾水。
我家是一层楼1100sqft,这是一个contractor给我的估价。。湾区需要烧暖气的时候不
是特别多,但也希望家里能温暖舒适一些。
请您给看看这2个是不是都太低端了。
The following items are included as part of the HVAC installation.
- Gas furnaces Bryant 311A, 80% efficiency, 70.000 BTU Single stage, 3 Ton.
- All sheet metal, boots, register.
- All ductwork, wire flex R-6.
- Thermostat, air filter, filter grill.
- Furnaces platform 3⁄4” plywood.
- Electrical circuit 120Volt, services light.
- Gas line, e... 阅读全帖
m****n
发帖数: 263
40
求教诸位大牛们,furnace奇怪的地方好多,就罗嗦一点希望能交代清楚。
刚买的房,Furnace是21年新的 Trane XL80.11月份查过,发现capacito快要换了。后
来就自己在amazon上买了换的。一切感觉都还正常。直到昨天降温到0F,有点担心,今
早就把不常去的房间的出风口关掉了。另外,昨晚捣鼓了一下whole house humidifier
,因为觉得太干了,不知道有没有关系(见下)。
一直不清楚humidifier有没有工作。前两天特别干,发现供水阀门关着,可能是两个月
前找人来service后忘开了。于是就打开了阀门,当时发现有点漏水,不多,就把阀门
略关小了点,就上班去了。到下午,老人打电话,回家发现furnace停掉了,toggle
switch旁边的插座都没电了 (humidifier就插在里面)。当时电闸位置都还在on上,
但是flip off从新flip on后,furnace又开始工作了。以为是电闸switch的问题,还以
为好了。
结果没过多久发现有一间屋子里面的出风口,出风特别大,而且暖气开始或者停止的时
候管道里都会有咚咚的声音。而别的屋子... 阅读全帖
s*******3
发帖数: 52
41
另外他建议furnace/ac全换,虽然我们的
furnace 还没坏,但是现在换的话,加个1600刀就能全换,如果现在只换ac,将来
furnace 坏了,要3,400刀来单换furnace, 因为到时候coil还要拆下来(铜管切断焊接
等),管道也要调整,因为新furnace 比旧的矮4,5寸样子,还要再申请一次permit,
人工费 都要加上,所以贵的多。现在换便宜很多。imore大牛给个意见, 有必要全换吗
?还是只换ac 呢?
w**********0
发帖数: 63
42
来自主题: Living版 - 换furnace+ac 请教imore等大神
老房子 家里准备彻底更新furnace及ac 因为在北方 冬季比较长,furnace准备选95-96
% AFUE的 空调就普通13seer就ok
找了几个contractor 问了几个报价 有些不明白的地方特来版上请教:
1. Contractor A推荐carrier的系统 59SP5(120k btu)furnace + 24ACB3 13seer
4ton AC
2. contractor B推荐trane的系统 XT95 (120k btu) furnace +XR13 13seer 5 ton
AC
价格上 A推荐的carrier系列6000出头 B推荐的trane系列7000出头
问题如下:
1. 关于carrier的furnace 有无必要上59TP6? 我看TP6的指标上写着多了two stage
gas valve,variable speed motor。我的理解是two stage可能主要在噪声上有所帮助
。59SP5指标写的single stage valve,ECM motor。ECM motor和variable speed不是
指一个概念么?貌似有些牌... 阅读全帖
d********e
发帖数: 267
43
这是当地的一个大公司,这一两年都用他们做一些简单的维护,倒是没有多收钱什么的
。最近发现attic的屋顶靠近furnace vent duct的地方有水,找人来看说是装的时候管
子短了,没有完全升出屋顶,冬天冷的时候就凝水了。这家公司报价把这duct全部换掉
,开价1200。因为furnace也20年了,所以要他们给换furnace也报个价,一看吓
坏了。大家看看这是不是骗子。还有,这种情况下只能把管子全部换掉吗?1200也
太贵了。
Option 1:
5 Ton Lennox 16 seer gas system, Condenser 14ACX-059 , Evaporator coil LH49/
62W9T,
Furnace EL180UH090 $11,500.00
Option 2:
5 Ton Lennox 14 seer gas system, Condenser14ACX--060, Evaporator coil CH35-
51, Furnace
ML180UH110 ... 阅读全帖
w**********a
发帖数: 64
44
来自主题: Living版 - Furnace + 空调 求建议
请教一下imore和各位行家关于furnace和空调。 家里的空调和furnace都快25年了,最
近想换掉。 房子坐标在东北,冬天冷,夏天可以接受。 两层,面积2000sqft左右,单
层大概1000 sqft。 大概什么样的furnace和空调就可以?
稍微调研了一下,想装一个2.5t, 2 stage, variable blower the furnace, 空调可能
选standard 1 stage, 13 -16 seer的。 quote了两家, 一个是Amana, 一个是Lenox.
价格差异特别大。Amana 大概$11000, Lenox $7500,参数都差不多,包安装等所有费
用。Amana的链接我附在了下边。 请问一下大家对这两个品牌有什么偏好吗?大概多少
费用比较合理?
Furnace link:
http://www.amana-hac.com/docs/default-source/default-document-library/cb-amvc9602a6350022fa6258827eff0a00754798.pdf?sfvrsn=0&mobiled... 阅读全帖
d********1
发帖数: 71
45
来自主题: NewJersey版 - 空调furnace系统求建议 (转载)
【 以下文字转载自 Living 讨论区 】
发信人: discover11 (:)), 信区: Living
标 题: 空调furnace系统求建议
关键字: 空调 furnace
发信站: BBS 未名空间站 (Sun Mar 13 23:39:55 2016, 美东)
家里要换空调,在nj,现在有几个选择:
1. Trane furnace:xv95,condenser:XR16(SEER17)+wifi touchscreen THERMOSTAT +
10 年 part warranty and 5 年 labor.
2. Lennox EL296 furnace, XC14(SEER14) + 2 stage THERMOSTAT. 10年part
warranty
3. YORK furnace:YP9C, condenser:YCJF(SEER14) + 2 stage THERMOSTAT 10年part+
labor warranty。
都是5 ton的系统,都是dealer负责安装。trane和lennox差不多价钱,york要便宜一点。
请问这几个组合里面哪套... 阅读全帖
A*********l
发帖数: 2005
46
【 以下文字转载自 Living 讨论区 】
发信人: AdamsMyIdol (F3), 信区: Living
标 题: 请教关于gas furnace 的问题
发信站: BBS 未名空间站 (Tue Dec 6 15:18:59 2011, 美东)
房子用的是gas furnace(搬进来才几个月)。最近天冷了,发现要用很长时间才能把
家里加热起来。
我把白天家里没人的时候的温度设成55度,然后从5pm 开始,设成70度。等到7pm回家
的时候,房间里才63度左右的样子(室外温度是32度左右)。
感觉热得太慢了。以前住condo的时候从50度加热到70度很快就好了,不过是用电的
furnace。我去gas furnace边观察了一下,发现它大概是这样工作的:燃烧加热一会儿
(感觉同时也在送暖风),燃烧停止,只能听见送暖风的声音。这样送一会暖风后,再
燃烧加热。房子的保暖应该可以,也没觉得哪里漏风。
就是觉得这个加热过程太慢,想问问家里用gas furnace 的,是不是都这样。
谢谢!
b****m
发帖数: 39
47
是比较慢.
你最近有没有换furnace filter? 这个通常可以自己做.
你若设五点,你的furnace应该四点多就启动,5点应该到你要的温度.
你可以自己再观察观察,如果你的房子漏风,furnace会启动频繁,温度还是应该上来
.你可以到每个屋子的出风口,感觉一下,离furnace近的vents, 热风应该是很大的.
在不行,你可以试试再往上查查你的furnace型号说明,或找professionals来看看.
m********e
发帖数: 4403
48
来自主题: Seattle版 - Furnace 停止工作了
精华区
4--> 3-->70 [合集] furnace 不work了
http://www.mitbbs.com/bbsdoc3/chinese.faq/Seattle/food/house/5
[合集] furnace 不work了
发信人: sonofagun (止戈为武), 信区: Seattle
标 题: [合集] furnace 不work了
发信站: BBS 未名空间站 (Sat May 5 14:33:18 2012, 美东)
☆─────────────────────────────────────☆
sky (天) 于 (Fri Mar 30 13:00:50 2012, 美东) 提到:
有推荐么?
以前用这个,服务,态度还行
http://eastsidehtg-ac.com/
就是有点贵,来一次119刀基本费,包括cleanup。
☆─────────────────────────────────────☆
Tutulover (Bunny) 于 (Fri Mar 30 13:18:16 2012, 美东) 提到:
先简单的自己试试:到你的ele... 阅读全帖
g*****9
发帖数: 4125
49
来自主题: Living版 - 想换furnace
gas furnace+duck work? If you do not have duct to begin with, a new furnace
+ all the duct work for 6300 is not too bad.
But if you only plan to replace the aging furnace, why replace the duct?
unless old one is leaking badly.
加上装 heat pump, I have never heard of such combination, heat pump use
electric heating element for back up heat when very cold outside if air
sourced.
Does he mean install a new heat pump for your upstairs and new furnace (but
keep the existing ac) for downstairs? Assume yo
k******a
发帖数: 169
50
来自主题: Living版 - 想换furnace
I google internet, maybe it is A Dual Fuel Heat Pump.
A dual fuel heat pump is an air-source heat pump designed to be installed
and to work with a forced air furnace heating system. The forced air furnace
can be new or existing, and can be fueled with natural gas or propane. The
dual fuel heat pump works in conjunction with your present furnace,
regardless of fuel type.
Does this make sense to you?

furnace
but
1 2 3 4 5 6 7 8 9 10 下页 末页 (共10页)