l*******e 发帖数: 4009 | 1 force air供暖,和AC是两个线路,所以房间里有冷风口也有暖风口。据我观察那个出
风口应该是出暖风的,但是不出风,导致温度比其他房间低不少。
老房子,手里也没有管道线路图(其实就算有我也不知道咋修)
这个情况是不是只能请人了?有DIY的可能么? |
d**j 发帖数: 7 | 2 You may check youself if there is a closed damper in this branch, otherwise,
you should hire a good professional to do a bunch of tests, such as airflow
of the duct, oversized system, undersized duct, return, or design issue of
the duct.
I mean a good contractor who can disclose the issue, not those cheap techs. |
l****u 发帖数: 980 | 3 冷暖气分别各自一套管道系统?没听说过。出风口和回风口吧?管道这么大的东西,跟
着看一遍,有没有关闭的地方、脱落的接头、被压住的软管、破损漏风,能修自己修,
不会就找人。 |
l*******e 发帖数: 4009 | 4 force air供暖,和AC是两个线路,所以房间里有冷风口也有暖风口。据我观察那个出
风口应该是出暖风的,但是不出风,导致温度比其他房间低不少。
老房子,手里也没有管道线路图(其实就算有我也不知道咋修)
这个情况是不是只能请人了?有DIY的可能么? |
d**j 发帖数: 7 | 5 You may check youself if there is a closed damper in this branch, otherwise,
you should hire a good professional to do a bunch of tests, such as airflow
of the duct, oversized system, undersized duct, return, or design issue of
the duct.
I mean a good contractor who can disclose the issue, not those cheap techs. |
l****u 发帖数: 980 | 6 冷暖气分别各自一套管道系统?没听说过。出风口和回风口吧?管道这么大的东西,跟
着看一遍,有没有关闭的地方、脱落的接头、被压住的软管、破损漏风,能修自己修,
不会就找人。 |
y****i 发帖数: 12114 | 7 先上个照片让群众们判定一下是出风口还是回风口。
【在 l*******e 的大作中提到】 : force air供暖,和AC是两个线路,所以房间里有冷风口也有暖风口。据我观察那个出 : 风口应该是出暖风的,但是不出风,导致温度比其他房间低不少。 : 老房子,手里也没有管道线路图(其实就算有我也不知道咋修) : 这个情况是不是只能请人了?有DIY的可能么?
|
l*******e 发帖数: 4009 | 8 给大家上个图,都是同一个房间里拍的,三个风口
这个是空调出风口,夏天开空调会出冷风的(已验证)
这个是我认为的暖风出口,摸起来有点温,没风出来(未验证)
这个是回风口,风向里进的(已验证) |
l****u 发帖数: 980 | 9 如果真像你猜测的那样一个冷风口一个暖风口,那这房子讲究,冷风从上出,暖气从下
出,合理。
出暖气的时候查了上面那个冷风口了吗?有没有暖气?大房间有几个出气口是常见的。
管道比较粗大,还是容易察看的。把挡的盖子拿掉,用手电、inspection camera看看
,阁楼、地下室看看,有没有脱落的接头。
【在 l*******e 的大作中提到】 : 给大家上个图,都是同一个房间里拍的,三个风口 : 这个是空调出风口,夏天开空调会出冷风的(已验证) : 这个是我认为的暖风出口,摸起来有点温,没风出来(未验证) : 这个是回风口,风向里进的(已验证)
|
l*******e 发帖数: 4009 | 10 好的谢谢,我再查查风口附近的管道
冷风口确实是没有暖气的
【在 l****u 的大作中提到】 : 如果真像你猜测的那样一个冷风口一个暖风口,那这房子讲究,冷风从上出,暖气从下 : 出,合理。 : 出暖气的时候查了上面那个冷风口了吗?有没有暖气?大房间有几个出气口是常见的。 : 管道比较粗大,还是容易察看的。把挡的盖子拿掉,用手电、inspection camera看看 : ,阁楼、地下室看看,有没有脱落的接头。
|
|
|
m*******p 发帖数: 1978 | 11 the first pic has the wrong register size, and the register is for return
air. are you sure this one has air out, not in?
the third register has a shutter. No return duct should have a shutter. |
d**j 发帖数: 7 | 12 Those DIY projects are without any rule when I saw the pictures, the ceiling
register secured on the quarter-round molding is ridiculous. So I guess
there are lots of mistakes done in the duct system.
You can use any grille on a return inlet but like this, it generates a lot
of pressure to the blower and could damage it very soon.
This system (at least those pics) has done something wrong on the duct
system, so finding a professional to correct those defects could be a smart
start.
【在 m*******p 的大作中提到】 : the first pic has the wrong register size, and the register is for return : air. are you sure this one has air out, not in? : the third register has a shutter. No return duct should have a shutter.
|
l*******e 发帖数: 4009 | 13 楼上两位说得对,这房子上上下下很多地方都是前房主DIY的,错误百出
不影响大局的我就不理了,现在着手修复明显影响使用的 |
y***1 发帖数: 583 | 14 检查一下炉子上面的各个出风管道,每个出风口都有一个开关。 |
d****n 发帖数: 6 | 15 你可以买一个thermal camera看到墙后面的冷/ 热管道。业余级别的thermal camera也
就200~300刀。也可以帮你明确验证到底有没有热气出来。如果如楼上所说有damper被
关掉了,你还能看到damper的位置,因为damper的一侧会是热的,另一侧是冷的。 |