M********k 发帖数: 16 | 1 I recently bought a 2-stories house in long island, and would like to keep
it's existing Hot Water Radiator heating, the house is 2500 square feet, and
will have 3 heating zones, and If I buy one tankless water heaters for hot
water and one for hot water heating, how many BTU of the machine I need to
buy, and which brand is good, need some suggestions from you, thanks in
advance. | i***e 发帖数: 9429 | 2
and
hot
Your house needs approximately 200MBtu Boiler, in order to find properly
sized boiler, ask someone to do a load calculation.
For tankless water heater, How many bathrooms does your house have?
【在 M********k 的大作中提到】 : I recently bought a 2-stories house in long island, and would like to keep : it's existing Hot Water Radiator heating, the house is 2500 square feet, and : will have 3 heating zones, and If I buy one tankless water heaters for hot : water and one for hot water heating, how many BTU of the machine I need to : buy, and which brand is good, need some suggestions from you, thanks in : advance.
| M********k 发帖数: 16 | 3 200MBtu?也许我没有说清楚,我打算买两个Tankless Water Heater , 一个是供暖,
一个是供热水,房子2500尺,供水的话,有3个full bath, 想知道大概这两个要买多大
的, 什么牌的机器好点?谢谢。
【在 i***e 的大作中提到】 : : and : hot : Your house needs approximately 200MBtu Boiler, in order to find properly : sized boiler, ask someone to do a load calculation. : For tankless water heater, How many bathrooms does your house have?
| G*****h 发帖数: 33134 | 4 每天有几人次洗澡?
不过电热水器跟人次关系不大,主要看同时洗澡的有几人?
【在 M********k 的大作中提到】 : 200MBtu?也许我没有说清楚,我打算买两个Tankless Water Heater , 一个是供暖, : 一个是供热水,房子2500尺,供水的话,有3个full bath, 想知道大概这两个要买多大 : 的, 什么牌的机器好点?谢谢。
| r***o 发帖数: 3058 | 5 供暖要 boiler , water heater 是供热水的, 2种不同的东西 。。
boiler 用的不是水, 是循环的coolent 一样的东西。。
【在 M********k 的大作中提到】 : 200MBtu?也许我没有说清楚,我打算买两个Tankless Water Heater , 一个是供暖, : 一个是供热水,房子2500尺,供水的话,有3个full bath, 想知道大概这两个要买多大 : 的, 什么牌的机器好点?谢谢。
| M********k 发帖数: 16 | 6 上网搜了搜,一般是hot water boiler供暖, 但water heater应该也可以供暖,因为
都是烧热水, 不知道有没有人知道。
【在 r***o 的大作中提到】 : 供暖要 boiler , water heater 是供热水的, 2种不同的东西 。。 : boiler 用的不是水, 是循环的coolent 一样的东西。。
| r***o 发帖数: 3058 | 7 water heatr 供暖是不是就不能有多个 zone 啦, 都是一个温度。
【在 M********k 的大作中提到】 : 上网搜了搜,一般是hot water boiler供暖, 但water heater应该也可以供暖,因为 : 都是烧热水, 不知道有没有人知道。
| M********k 发帖数: 16 | 8 You can still have multiple heating zones with hot water heating, it may
require the boiler has a higher GPM, I think.
【在 r***o 的大作中提到】 : water heatr 供暖是不是就不能有多个 zone 啦, 都是一个温度。
| i***e 发帖数: 9429 | 9 我想你大概想装hydronic heating system吧,你这个需要120Mbtu coil,我想用hot
water boiler 比较好,主要是够力。tankless water heater 用在40Mbtu-80Mbtu 比
较好。
用热水的tankless water heater 你家用7.5-8.4 GPM. 如果预算足够,上9.5GPM.
Rheem. A.O Smith, Rinnai, 都行。
【在 i***e 的大作中提到】 : : and : hot : Your house needs approximately 200MBtu Boiler, in order to find properly : sized boiler, ask someone to do a load calculation. : For tankless water heater, How many bathrooms does your house have?
| M********k 发帖数: 16 | 10 我现在是打算用hot water boiler, 现在在网上找boiler, 不知道160 DOE(MBH)够不
够, 有没有可以推荐的?
热水的话是我是准备用tankless water heater。
【在 i***e 的大作中提到】 : 我想你大概想装hydronic heating system吧,你这个需要120Mbtu coil,我想用hot : water boiler 比较好,主要是够力。tankless water heater 用在40Mbtu-80Mbtu 比 : 较好。 : 用热水的tankless water heater 你家用7.5-8.4 GPM. 如果预算足够,上9.5GPM. : Rheem. A.O Smith, Rinnai, 都行。
| | | i***e 发帖数: 9429 | 11 这玩意将来还有好多升级空间,你要请师傅去做计算。
使用寿命达30-50年,那些老牌子都行。
【在 M********k 的大作中提到】 : 我现在是打算用hot water boiler, 现在在网上找boiler, 不知道160 DOE(MBH)够不 : 够, 有没有可以推荐的? : 热水的话是我是准备用tankless water heater。
| M********k 发帖数: 16 | 12 刚开始打算的取暖方式是HVAC,请了公司来评估,他们设计的是2个90000 BTU的
Furnace, 95%AFUE, 如果现在用hot water heating的话是不是只要买一个BTU大致相
当的Boiler, 也就是DOE(BTU)在170000左右的?
【在 i***e 的大作中提到】 : 这玩意将来还有好多升级空间,你要请师傅去做计算。 : 使用寿命达30-50年,那些老牌子都行。
| i***e 发帖数: 9429 | 13
你的房子需要10-12万btu(heating btu) hydronic air handler 或hydronic heating
coil.可以用17万btu 的tankless water heater, 20万btu 的较给力。12万btu 都是5
吨的blower,你的房子需要4吨的blower就够了。还得请当地师傅去做heat load 计算。
【在 M********k 的大作中提到】 : 刚开始打算的取暖方式是HVAC,请了公司来评估,他们设计的是2个90000 BTU的 : Furnace, 95%AFUE, 如果现在用hot water heating的话是不是只要买一个BTU大致相 : 当的Boiler, 也就是DOE(BTU)在170000左右的?
| M********k 发帖数: 16 | 14 iMore, 先谢谢你的回复, 我今天在网上找了一个BOILER去申请permit了。帮我看看这
个正么样:
Williamson, GWC-175, A.G.A. input 175(MBH), DOE Capacity 161(MBH)
heating
是5
【在 i***e 的大作中提到】 : : 你的房子需要10-12万btu(heating btu) hydronic air handler 或hydronic heating : coil.可以用17万btu 的tankless water heater, 20万btu 的较给力。12万btu 都是5 : 吨的blower,你的房子需要4吨的blower就够了。还得请当地师傅去做heat load 计算。
| i***e 发帖数: 9429 | 15
你的回复让我觉得我前面和你说的都不对,全是两码事.
我再回到第一楼,我那天也只是大约看了一下,因为我想这些都大同小异的, 根据你的
室内面积大致推算出来。
其实我在2楼的回答是正确的.我指的20万btu boiler,通常是指市场上最低81% 的标准
机子,那output 也就是16万2千btu.
Williamson GWC-175 是92%的高效率机子,output 为16万1千btu。我比你的师傅算出
来的只多了1000btu,等于没啥差别。
【在 M********k 的大作中提到】 : iMore, 先谢谢你的回复, 我今天在网上找了一个BOILER去申请permit了。帮我看看这 : 个正么样: : Williamson, GWC-175, A.G.A. input 175(MBH), DOE Capacity 161(MBH) : : heating : 是5
|
|