发帖数: 3060
1
是不是接任何一根火线跟地线就好啦?
this is correct.
The 200V you have is likely to be 208V, which is Sqrt(3)*120V, so you are
fine just to connect one 120V and neutral, which gives you 120V.
measure it first!
y****a
发帖数: 1140
2
【 以下文字转载自 amazondeal 俱乐部 】
发信人: yangwa (阳阳), 信区: amazondeal
标 题: 车用 | $132.60 (56% off) Cobra 12V DC to 120V AC Power Inverter
发信站: BBS 未名空间站 (Wed Nov 27 14:17:35 2013, 美东)
$132.60 (56% off)
Cobra 12V DC to 120V AC Power Inverter
http://www.amazon.com/dp/B00126K8DA/ref=gb1h_tit_c-2_6362_b30cb
y****a
发帖数: 1140
3
【 以下文字转载自 amazondeal 俱乐部 】
发信人: yangwa (阳阳), 信区: amazondeal
标 题: 车用 | $132.60 (56% off) Cobra 12V DC to 120V AC Power Inverter
发信站: BBS 未名空间站 (Wed Nov 27 14:17:35 2013, 美东)
$132.60 (56% off)
Cobra 12V DC to 120V AC Power Inverter
http://www.amazon.com/dp/B00126K8DA/ref=gb1h_tit_c-2_6362_b30cb
G*******s
发帖数: 10605
4
【 以下文字转载自 SmartShopper 俱乐部 】
发信人: GoRockets (火箭加油), 信区: SmartShopper
标 题: APC Back-UPS ES 8 Outlet 550VA 120V $39.99
发信站: BBS 未名空间站 (Mon Dec 24 23:09:22 2012, 美东)
OfficeMax has APC BE550G Back-UPS ES 8 Outlet 550VA 120V for $49.99 - 20%
with promotion code FRIEND20 = $39.99 with free store pickup. Coupon expires
midnight Dec 25th.
http://userquote.com/forum/index.php?topic=1677.msg1958#msg1958
a*******r
发帖数: 7558
5
有个700瓦120v的电器带回来用,哪些牌子电压转换器比较好?
北京有哪些店可买?
j*********3
发帖数: 1284
6
来自主题: Classified版 - 出售 fusing unit 120V
fusing unit 120V
A0P0R73333
new.
请PM
l******e
发帖数: 1875
7
找的电工说如果装110-120v的hood就从厨房里抽根线出来,如果装220v的hood就从车库
的panel里新加一条电线。不知道这种做法靠谱不?
N*****s
发帖数: 227
8
1)买到大功率的电器时,要用到220V电压时,又要改造,花钱花时间
2)同是一样用途的机器,120V的就是家用的,220V就是commercial的。价钱差几倍。
我去,中国的家用机器都是commercial的呢。
t*******y
发帖数: 2424
9
120v要安全的多。
s**********d
发帖数: 36899
10
美国240V线每条线对地还是120V,手碰上去还是死不了人。
中欧的220V是对地的,碰到火线就是220,会死人的。
a**********r
发帖数: 150
11
房子原来的gas dryer坏了,我就将以前带来的一个electric dryer翻了出来,可惜是4
prong 240V的,与房子原来的3 prong 120V outlet配不上。
没办法,只好去买了一根3 prong的线接上electric dryer, 试了一次,好像能工作,
就不知道问题会不会很大。哪位有经验的大大给指点一下,不行就准备去买台新的gas
dryer换上了。
a**********r
发帖数: 150
12
我也担心电压不匹配会将房子烧了,如果将120V的outlet换成240V,会不会很麻烦?如
果请电工改线,估计也得好几百。
谢谢。
y*j
发帖数: 3139
13
这种工程还是请电工吧,不是简单把线接起来的问题,还要考虑很多因素。

:我也担心电压不匹配会将房子烧了,如果将120V的outlet换成240V,会不会很麻烦?
如果请电工改线,估计也得好几百。
:谢谢。
a**********r
发帖数: 150
14
谢谢老大指点。
我刚在AMAZAON上订了个电压测量仪,等到了测完电压再看。家里的outlet应该是120V
的,不想改电路,太麻烦。
不行就直接买个新的gas dryer,也就六七百,估计和请个电工的价钱差不多。
s**********d
发帖数: 36899
15
120/240插座完全不一样,一看就知道了,不用量

120V
e****7
发帖数: 4387
16
建议你去买Gas dryer

120V
d*****a
发帖数: 17
17
我的power supply是200V的三相电,但是我要用的电器需要120V的单相电。
是不是接任何一根火线跟地线就好啦?有哪里卖这种转插的么?请懂得的人详细说明,
谢谢!
w*******y
发帖数: 60932
18
APC Back-UPS ES 8 Outlet 550VA 120V:
http://www.frys.com/product/5582280?site=sr:SEARCH:MAIN_RSLT_PG
$39.99 - $10 Rebate:
http://images.frys.com/art/rebates_pdf/5582280_092410.pdf
= $29.99 + Shipping or Free In-Store Pickup
Shipping was $11.49 for me.
i***e
发帖数: 9429
19
来自主题: Living版 - 为啥还有220v 的啊?

大哥请息怒,没有违背您的意思。
最近40年的住宅应该已经没有三相电接入,可不代表以前没有,据我所知比华利山有些
较老的房子是有拉老三相电的,其它地区肯定也有,只是少而已。
商业/住宅单相 120V/240V, 2 legs.
Line 1 to Neutral ----- 120V
Line 2 to Neutral ----- 120V
Line 1 to Line 2 ----- 240V
商业/住宅 三相120V/240V Delta --- 又称老三相, 3 legs.
Line 1 通常用黑色标记,Line 2 通常用红色标记,Line 3 通常用蓝色标记。
Line 1 to Neutral ----- 120V
Line 2 to Neutral ----- 208V
Line 3 to Neutral ----- 120V
Line 1 to Line 2 ----- 240V
Line 1 to Line 3 ----- 240V
Line 2 to Line 3 ----- 240V
商业三相120V/208V wye, 3 legs.
Line 1 ... 阅读全帖
i***e
发帖数: 9429
20
来自主题: Living版 - 怪异的插座,求问懂电的高人
哈哈, 你这打击一大片啊。
别着急,慢慢来,家居版的实力还是有目共睹的哦。给自己点耐心。
如果我的话,我会拆开那个GFCI插座:用万用表
1)先量GFCI插座上游(INPUT 端)
确认“零线"(银色螺丝头)和 “火线”(铜色螺丝头)之间是否有120V?
确认“火线”(铜色螺丝头)和“地线”(绿色螺丝头)之间是否有120V?
然后万用表设在“Continuity”档,确认“零线"(银色螺丝头)和“地线”(绿色螺
丝头)之间是否会呻吟。
上面3项全满足后。
2)再量GFCI插座下游(OUTPUT端)-- 记住下面量的都是OUTPUT端
确认“零线"(银色螺丝头)和 “火线”(铜色螺丝头)之间是否有120V?
(***我估计电压不到120V***)
确认“火线”(铜色螺丝头)和“地线”(绿色螺丝头)之间是否有120V?
(***我估计电压不到120V***)
然后万用表设在“Continuity”档,确认“零线"(银色螺丝头)和“地线”(绿色螺
丝头)之间是否会呻吟。
***“地线”(绿色螺丝头)*** 只有一个(input 和 output共用)
你把测得的数数值贴上来,大家基本可知道到... 阅读全帖
t**d
发帖数: 6474
21
你又错了。美国的neutral线是不接地的。有些人不懂,认为neutral跟地线是一回事,
经常把地线做neutral,结果家里有的灯太亮,有的太暗。
关于相位,要谈相位,不能独立谈,因为他跟电压电流是一起的,也需要一个参考点。
我们说的120V,是指120V相对neutral,另一个火线的120V也是相对于neutral,而这两
个120V火线在某一刻相对于neutral的正弦曲线的点,一个是正的,一个是负的,这两
条曲线相位正好差180度。其实,如果不看电源是怎么来的(其实也没必要看),单纯
用仪器去测量这个两个120V火线,测出的结果就是他们之间相位差180度。明白了吗?
x**8
发帖数: 4844
22
这两根hotwire哪根上,哪根下没分别。原理是这样的:
- 从电公司过来的是那两根hotwire(s)和电公司的电传输“地”(neutral wire)。
- 每根hotwire相对neutral wire是120V,但这两根hotwire的电又相位相反。你可以想
像成一根+120V,另一根-120V。
- 需要120V的时候,你需要一根hotwire(任何一根都行)加一根neutral。
- 需要240V的时候,你需要两根hotwire,不需要neutral。
- 需要240V+120V的时候(比如家里的烘干机),你需要所有两根hotwire,外加一根
neutral。
当然,那根bare/green wire是住家这边的接地线(每家都有一根很粗的铁棍似的线钉
入地里,比如俺家的在电表附近的墙边),总是需要的。这根“地”在主panel上是和
“neutral"接在一起的(sub-panel 上不是接在一起的)。
O*******d
发帖数: 20343
23
Most electric appliances use either 120V or 240V in North America. How do
you get 120V/240V from a 3 phase system? I guess you can get 120V and 208V
from a 3 phase system, not 120V and 240V.

.
elevator).
i***e
发帖数: 9429
24
来自主题: Living版 - [咨询]冷暖气、冰箱故障
接着同样暖气要开着,看我更新的图,拔掉“CAB”那个线头,
测电子板上的“CAB”和任何一根NEUTRAL线之间是否有120V?(紫色和灰色圈线)
CAB stands for Combustion Air Blower, CAB 那根线就是小排气马达的火线。
如果“CAB”和“Neutral”之间测出来有120V电压,那么在上方你拔掉排气马达接线的
那个位置也要有120V。我们再继续下一步。
如果“CAB”和“Neutral”之间测出来没有120V电压,那么电子板上的那个“K3”继电
器出问题了。
y*****n
发帖数: 11251
25
美国家庭是用split-phase供电。单相220/240v从电站到户。然后分成两个120v的电压
。家里的115/120v接口接到两个120v电压中的一个。220/240v电压就是两个120v的串联
。所以不管110还是220v,都是single phase。
y*******n
发帖数: 10103
26
2个插头的是 火线(line)、零线(neutral)。
3个插头的是 火线、零线、地线(ground)。
有的大功率电器用2个火线加一个地线。电压等于一火线的根号3倍或者2倍。
以上这都是单相电。
美国的民用电压是208/120v三相,或240/120v split phase,
一根火线配零线是120v,2根火线就是208v或240v。
三根火线还是208v。当然240/120v只有2跟火线。
三相供电至少要4个插头:3火线加地线,有的还要零线。
y*h
发帖数: 25423
27
来自主题: Military版 - 说到太阳能,你德眼光放远一些

那个电源线应该有4个极,其中两条相线,各120V,相位相反,一条零线,一条接地线
。其中240V给烘干机的加热电热丝供电,120V是给其电机和控制电路供电。
120/208是你的烘干机在三相电路中使用时的情况,120V是单相对零线电压,208V是两
条三相线的线间电压。一般家庭都是第一种情况的双相电,工业场合采用三相电。

发帖数: 1
28
【 以下文字转载自 Tesla_Club 俱乐部 】
发信人: sdsdsdsd (sdsdsdsd), 信区: Tesla_Club
标 题: 自己动手车库装NEMA 14-50插座
发信站: BBS 未名空间站 (Tue May 8 23:39:28 2018, 美东)
当年下单订了MS, 要等三个月拿车,
话说等车的几个月里, 兵马未动, 粮草先行。 车库里原来只有几个120V的插座。相
比240V充电(专业术语叫Level 2) 用120V充MS (叫Level 1), 不但充得慢, (
240V x 40A = 9.6KW, 大约一小时充30Mile, vs。 120V x 15A = 1.8KW, 大约一
小时充5Mile), 而且效率低 (8x% vs 7x%), 多付电费。 养个纯电车, 装个240V插
座应该是必须的。
网上看了找电工开销大概从5,6百到一两千不等。 跟布线难度, 市政许可,地域,
及电工斩人程度有关。
本叔自我感觉动手能力相当可以。 自己搞定应该不在话下。
免责声明: 高压危险警告!!! 本帖仅供参考。 本叔不负任何法律责任。
O*******d
发帖数: 20343
29
In North America, regular residential houses are served with SINGLE PHASE,
CENTER TAPPED 120V/240V system. This system has 3 wires, two hot and one
neutral. The voltage between each hot wire and neutral wire is 120V. The
voltage between two hot wires are 240V. Most room receptacles are wired
between a hot wire and the neutral wire, providing 120V. Large electric
appliances, such as stove, oven, cloth dryer and central AC are using
electricity supplied from the two hot wires.
A 3 wire system
l***u
发帖数: 26081
30
来自主题: Living版 - 请问一种电器零件
请问市面上有没有这样一种电器零件,能够周期性的给两个电器轮流供电
输入:120V,
输出A:120V
输出B:120V
A和B能被轮流供电,如果在A和B上分别接灯泡,这两个的灯泡就会一直闪烁。
这种零件叫什么,在那里能买到?
谢谢。
q**********i
发帖数: 127
31
You'll often hear voltages in your home referred to as 110V, 115V, or 120V.
This can be confusing but the bottom line is they are referring to the
exact same thing. 120V is the AC voltage on a single hot wire in your home
with respect to neutral (or ground). With resistance in the wiring in your
house, this 120V will likely have dropped to 115V by the time it gets to the
appliance you are powering. At the end of a long extension cord you could
even drop to 110V. This is why you'll see the dif... 阅读全帖
g***e
发帖数: 4074
32
来自主题: Living版 - 空调风扇问题求助
多谢!我已经研究过了,发现blower control board坏了。在网上订了一个可以替代当
前这个型号的,过两天就到。不过这两天热啊!
稍微详细地说一下,这种压缩机工作,风扇不工作的情况,正如imore大侠所说,我也
是这么做的:
首先测thermostat的G和R之间是否有24-28V的交流电压,忘了是fan on状态还是off状
态了,反正这两个状态一个是有24-28V电压,一个是没有,否则这个线路可能有问题;
然后本来要测那个马大并行的电容是否有问题,不过家里万用表不能测电容,所以先忽
略,因为可以从后面的测量来反推是否电容有问题;
好了,这下面一步就是imore说的测量blower输出到fan的黑线和白线之间是否有120V(
我家blower用120V电源)。这里要注意打开blower的面板时有一个switch,保证面板开
的情况下blower没有带电,这个很有用,同时操作的时候也要注意安全。我发现连接电
扇转子的黑线和白线之间在控制上应该是fan on的状态下没有相应的120V交流驱动电压
。问题基本可以肯定是control board坏了;
最后我用刚才说的那个swi... 阅读全帖
i***e
发帖数: 9429
33
我曾今搞过个类似的, 不过不是孵蛋
最简单的话就去搞个鱼缸,吊个CPU FAN,装个白炽灯泡,然后用数字温控器去控制温
度。
数字温控器的话可以参考
johnson controls A419 120V/240V--- 我以前就用这个, 这个出了最早
ranco ETC-111000(120V/240V) /ETC-112000(24V),这个是后来出的
emerson 16E09-101, 24V/120V/240V这个是最近5年出的。
这3款都类似的,价位应该也是最便宜了。
m*f
发帖数: 8162
34
来自主题: NewJersey版 - 问问家里有发电机的同学们
要看什么样的发电机。extension cord没啥用。
“240v输出那里要买一个split成120v的,这样才balance power output”
这句话应该是误解,发电机上面肯定有120v的输出的。240v的是用于直接连到transfer
switch或者直接连到service panel,上面有两根火线,各120v,相位差pi,所以加起
来是240v。

ex
p
G********d
发帖数: 10250
35
【 以下文字转载自 HiFi 讨论区 】
发信人: Dotaallstars (Dotaallstars), 信区: HiFi
标 题: 【报名】人数达批次要求数量,周日5pm EST截止报名
发信站: BBS 未名空间站 (Fri Sep 9 14:03:46 2011, 美东)
新电路板已经开始印刷。
因为电路器件经过了优化和高阻校声,重新选择了输出电容,电子管精确配对。所以机器型号厂家改为了708 reference。前后面板有mitbbs的纪念字样。如果需要普通版本机壳的朋友,请在付款时候说明,也同时说明面板颜色。
最新更新:
和708b厂家技术电话过了一遍电路,作为三极管接OTL放大器,阻容输出的输出级电容质量对音质有着比较大的影响,大功率输出时的信噪比也需要花时间校音。现在作为有特色的电容,厂家囤货有古董油浸电容和法国苏伦,因为古董电容的批次不同可能会导致质量参差不齐,所以还是选择苏伦,因为尺寸问题,PCB可能需要从新设计。不过机壳喷漆也需要时间,所以并不存在需要等待的问题。以前市场上销售老版本708B和现在要上的新电路和新器件,差距还是比较大。以前有一个风骚的装饰窗,... 阅读全帖
d*b
发帖数: 21830
36
你们这些傻逼,人模狗样的,都忘了自己是偷渡过来的了
1.两个相位差180度的120V电压,加起来变成240伏
2.他妈的120v比240伏更容易击穿
18世纪的物理学都要被你们这些偷渡佬改写了
a*******9
发帖数: 239
37

你这种相位差180度的说法,严格来说是错误的。因为交流电从电厂出来,经过高压输
电,配电站到小区,对于每户的输入,取的是一相,如2.4KV,再通过最后一级变压器
入户,次级同一绕组中间抽头,得120V/240V输出。
小区内的负载,可以通过不同的相均衡。
所以美、加民用电,单相120v/240v没错。
f****e
发帖数: 24964
38
三相的相电压是120V,到用户的240V是怎么来的呢?
单相四线是不是要先升到240V,然后分一半是120V?

Line
g********b
发帖数: 8461
39
来自主题: Automobile版 - 别拿文科生不当高科技人才
额。。。。
美国供电都是3根线,其中1根零线,2根120V的火线。每一根火线和零线之间是120V AC
,这2根火线之间有一个pi的相位差,所以这2根火线之间是240V AC。所以我说,美国
的240V和国内的220V还是有很大差别的,用电器设计也不太一样。至少美国这边的240V
是60Hz的。
l**********3
发帖数: 2088
40
来自主题: Food版 - 220伏 VS 110 伏
110v = 120v = 110/120v = 115 v
d****2
发帖数: 6250
41
来自主题: Living版 - 怎么换电插座

米国240V 120V拉线确实挺搞的,当然用120V应该安全些。
a**u
发帖数: 8107
42
来自主题: Living版 - 厨房插座没电了
就是带GFCI的outlet没电了,把outlet和GFCI拆下来,换到别的正常的地方,发现GFCI
是没问题的。测试了一下 incoming的电压,发现hot to ground还正常,是120V,但是
hot to neutral就不对了,大概80~90V,而neutral to ground居然还有20多伏特。正常
的情况是不是应该hot to neutral也是120V,而neutral to ground是应该0V的?不太懂
电的东西,但是incoming wires都在墙里,我咋找毛病啊
g**********5
发帖数: 112
43
来自主题: Living版 - 美国电力通讯常识简介(三)
美国的电压
美国电压标准(ANSI C84-la-1980)的规定: 1.供电系统设计要按“范围A”进行,
出现“范围B”的电压偏差范围应是极少见的,出现后应即采取措施设法达到“范围A”
的要求。 2.“范围A”的要求: 115~120V系统:有照明时:用电设备处110~125V;
供电点114~126V。无照明时:用电设备处108~125V;供电点114~126V。 460~480V
系统:(包括480/277V三相四线制系统) 有照明时:用电设备处440~500V;供电点456
~504V。无照明时:用电设备处432~500V;供电点456~504V。 13200V系统:供电点
12870~13860V。 3.电动机额定电压:115V、230V、460V等。照明额定电压:120V、
240V等。从美国电压标准中计算出的电压偏差百分数:对电动机;用电设备处(电机端
子)无照明时+8.7%、-6%,有照明时+8.7%,-4.4%;供电点+9.6%,-0.9%。对照明:用
电设备处+4.2%,-8.3%;供电点+5%,-5%。对高压电源(额定电压按13200V):照明+5%
,-... 阅读全帖
s*8
发帖数: 1933
44
不可以的,美帝国主义已经进入衰老期,这么简单的事情也能搞得很复杂,240v是一根
120v,另外一根也是120v,但是相位差180度。所以其实两根都是火线。
中国的220v是一根220v,另外一根是零线,虽然零线不是地线,厂家设计的时候很可能
检查不是很严密,因而有可能会把零线与豆浆机外壳相连,如果你插到美国的假240v上
,很可能会有危险。

220V
k**n
发帖数: 3989
45
来自主题: Living版 - 到底该买那个神器
AP238-PS13-30
Features
Mounting version: Under cabinet
Available Dimension: 30" x 22" x 11.7" (W x D x H)
Voltage: 120v @ 60 Hz (USA & Canada Standard)
Speeds: 4 Speeds with Timer Function
Airflow: 385CFM / 490CFM / 615CFM / 900CFM
Noise Level: Low Speed: 46 dB to Max Speed: 69dB
Motor: Ultra Quiet Dual Squirrel Cage Motor
Keypad: Touch Sensitive Control Panel with Blue LED Lighting
Lighting: 2 x 20 W Dimmable Halogen lights
Venting Size: 8" Round Duct Vent on Top
Filters: Dishwasher Safe Stainl... 阅读全帖
A******D
发帖数: 1075
46
不是220V,是240V.美国一般电也不是110V,是120V.120V的电是火线到地线;如果是两
个火线,相位相反,那么就是240V.
p*******r
发帖数: 152
47
来自主题: Living版 - 美国的住家电力系统
我来替楼主完善一下。
我是做这方面的工程师,但是是做industry的,所以略知一二。
楼主所说的这种家用panel board属于single phase wall amount panel. voltage
level is 120V,the voltage is 120V across one pole circuit breaker and 240V
across two pole circuit breakers. 如果是three phase的话,voltage通常是480/
277.208/120, 两边分别代表线电压(line voltage)和相电压(phase voltage). 楼主
提到的矢量发通常就是用于计算三相电压的啦。 但是在single phase下我们很少提到
矢量这个概念了。 顺便提一下美国的高压输电,大家可能比较关心。 美国的输电电压
等级通常为500KV,230KV,115KV,63KV,12KV。 比中国差多了,现在中国都开始玩正
负800KV直流和1000KV交流输电了,美国就是个屁股。 哈哈
o**h
发帖数: 246
48
来自主题: Living版 - 问个发电机接线的问题
一个发电机接线的问题. 请大家解惑.
前段时间停电时买了个Generac 5500 发电机. 有两个120v outlets, 一个240v outlet
. 带根十尺长cable可接240v的outlet. 由于我决定把发电机接到房子的总线上, 于是
把带来的cable母的那头去掉, cable里有黑,红,白,绿四条线. 再把家里的电表箱打开,
把电表摘下来, cable的黑线和红线分别接上进屋的两条火线, 白线和绿线都接到
neutral-ground bar. 如此用到来电一直很好. (那两个120v outlets就没有用.)
今天上班没事, 上网看到有人讲不应有多点零地相接. 我的发电机上写明是neutral
bond to frame. 而neutral-ground bar是另一个零地相接点. 网上讲, 象这样的情况
应该找到发电机的零地相接点, 把它断开.
请懂电的朋友告诉我, 有必要断开发电机的零地相接点吗? 多点零地相接到底是如何有
害的.
1 2 3 4 5 6 7 8 9 10 下页 末页 (共10页)